307.2.1.1 - Condensate drainage [F] (202) 783-2348 On 2021-03-20 I think the builder cramped as much into that small space to save money. The Sanicondens Best Flat is capable of serving multiple mechanical systems up to a combined total of 500,000 Btu per hour. What is the inside diameter minimum of condensate drains. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Understand code requirements for condensate disposal per International Mechanical Code. Demonstrated abilities in cementing healthy relationship with clients and leading workforce towards accomplishing business and corporate goals.<br>4. An auxiliary drain pan with a separate drain shall be provided under the coils on which condensation However a read of manufacturer's installation instructions can provide further advice. Examples of approved areas include a trapped and ventilated receptor to a sanitary sewer, and a downspout that terminates to an approved area. Watch out: Your local building code compliance officer is the final legal authority on this question. The rub may come if the standpipe diameter is too small to admit both the washer drain and the clip holding the condensate drain at the same time. We have no relationship with advertisers, products, or services discussed at this website. [8] "GE Zoneline Owners Manual and Installation Instructions, Heat/Cool Model 2900, Heat Pump Model 3900", General Electric Corporation, [copy on file]. Energy code: Section 503.2.8 Piping insulation. overflow of the primary drain pan or blockage of the condensate drain piping. IMO, Sure that can work, provided the tubing carrying condensate to the drain is routed such that it passes above the flood rim of the sink. Where should the air conditioner or heat pump condensate drain be connected - where are we permitted to dump condensate? Mechanical Engineering. DiversiTech_61838L . Mr. Kahn is a licensed home inspector in New York and New Jersey, and can be reached at Website: ICC, International Code Council, 500 New Jersey Avenue, NW The picture in the article for a 5 ton system would NOTt be nearly enough to overcome the negative air pressure caused by draw-through air pressure and thus result in coil pan pan spillage. 3345 Sunrise Blvd.Suite 5Rancho Cordova, CA 95742, Mon Fri: 7:30 am 5:00 pmSat: 8:00 AM 2:00 PMClosed Sunday, HomeAboutServicesFinancingReviewsLearning CenterService AreasContact, Mitsubishi Variable Speed Ducted Heat Pump, get your official Fox Family merch available on Teespring.com. This creates a nuisance area of slippery water that, over time, can even start creating algae which are even more slippery. Condensate drain hose trap 5. Coil shall be tested at 500 psi (35 kg/sq.) The conventional gas-fueled tankless water heater produces hot exhaust that also contains acidic moisture from the combustion process, and has to be vented through a corrosion-resistant chimney. We discuss air conditioning, heat pump & condensing boiler or furnace condensate drain leaks, locations, causes, repairs. . They require sufficient oxygen to burn clean and safely, without soot and CO (carbon monoxide). Before we worry too much let's find out if there is a concern, that is, is there actually a problem of condensate forming on the outside of the condensate drain line and in sufficient quantity to wet the interior of the return ducts (which isn't a great place to rout pipes of any sort). To get the data we need to design systems that mitigate those issues, we need to do a blower door test. The complex is now owned by a new owner and he has contacted us about why we didn't insulate the condensate drain lines that are inside the return air in an air conditioned space. I often find that the flexible condensate drain tubing is not carefully installed nor supported to maintain drainage slope throughout its run. Dov Ber Kahn, a home inspector in Rockland County, NY has contributed photographs of various building features. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References. mechanical service equipment; electrical components; automotive; domestic refrigeration; . Thank you for a helpful question. When the mixture returns to its use temperature, the condensation will transform back to the gaseous state. This applies to gravity / natural drain with no condensate pump assistance. So, if we are supposed to drain the primary into the drainage system of the house, can we terminate the drain line over a gutter and let the water fall into the gutter, where it will continue to the ground to an approved area? 4. 510(a)- "Condensate from air-cooling units, fuel burning condensing appliances and the overflow from evaporative coolers and similar water- Find many great new & used options and get the best deals for Evaporator Coil Condensate Drain Trap EZT-113B - BUY MORE & SAVE!!! Sharing a condensate drain downstream from the AC unit MIGHT be OK provided its capacity is not exceeded and of course that the condensate drain is installed to drain to an acceptable location (such as outdoors, not onto a sidewalk etc) and terminates where it won't be blocked by snow, shrubbery, etc. How far away from a florida heat pump can I install the condensate p-trap. Learn how your comment data is processed. IMC 307.2.3 states that all HVAC equipment that produces condensate must have either a secondary drain line or a condensate overflow switch, a secondary drain pan with a secondary drain line, a condensate switch, or some combination of these installations should be used to prevent overflow if the primary drain line blocks. The widely used reference is the IMC, which stands for International Mechanical Code. - use an Appliance Wye to connect a condensate drain to an existing washing machine standpipe or other drain. Are these considered the same item or are the pump and lines two different items? Or see CONDENSATE DRAIN CLEAN & DE-CLOG FAQs questions & answers about how to handle HVAC condensate drainage, posted originally on this page. Some home inspectors and HVACR technicians want the drain to be insulated either to cure an actual observed wetting problem OR because they're making their own, probably unnecessary, interpretation of one of the model energy codes. I doubt that all traps are filled with water all year. CONDENSATE DRAIN INSULATION REQUIREMENTS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. cooling coil or fuel-fired appliance that produces condensate: 1. Let's not mix apples and oranges here. It may not be defined as a public walkway, but it would still be a nuisance for the homeowner and family members who must walk through that wet spot every day during normal activities. The company Little Giant makes a wide variety of pumps including condensate pumps, pony pumps, and others; --- Only one image can be added per comment but you can post as many comments, and therefore images, as you like. @V.F.G., usually there's no problem sharing that drain between condensate vent and washing machine; CMC 310.3 says condensate waste pipes must be made from materials designed to work with that type of condensate drainage. Code: 2018 North Carolina Mechanical Code Date: March 15, 2019 Section: 307.2.3, 307.3 Code: 2018 North Carolina Residential Code Date: March 15, 2019 . Steam trap c.Steam Loop d. Steam tap. Pressure Vessel 12. A short length of clear vinyl tubing will complete the connection to the P-trap. Condensate or waste water shall not drain over a public way. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Don't dump condensate in places that could cause people to slip. In the photo the white flexible condensate drain tubing is being routed down from above where a split system A/C unit is to be hung on the wall. Please find your question repeated along with a detailed reply now at Which allows only condensate and gases to drain from steam pipe lines a.Traps b. . DariaI want to help but am stymied: the decision to include or not the actual drain line as part of the condensate pump system is going to be in the tiny mind and hands of the insurance company's adjuster department. Why would we be worried about draining our condensate liquid into the rain gutter? And the typical application in the install guide only shows this line running to a floor drain, and of course includes an air gap. Only the discharge of the condensate is regulated by the plumbing code, not the connection of the piping to the mechanical equipment. Notice that one of the most common condensate disposal locations, connection to a plumbing stack vent pipe, is not recommended and is prohibited by building code in some jurisdictions. HOWEVER, new wording was added in IMC 307.2.4.1 that states that ductless systems must either have a check valve or a trap in the condensate line. Examples of Model Building Codes Condensate Disposal Regulations & Recommendations. And I see far too many systems without a cleanout on them. A water supply shall be provided for cleaning, flushing and resealing the condensate trap, and the trap shall discharge through an air gap in accordance with Section 608. steveray Sawhorse Joined Nov 25, 2009 Messages 10,006 Location West of the river CT May 1, 2017 #7 802.1.5 Nonpotable clear-water waste. Mechanical Engineering questions and answers. Originally, I think the builder had connected the drain pan on the left direct to the drain outlet, but the pan is lower than the outlet. See attached pic for mock-up. According to the IMC, 3/4 is sufficient for up to 20 tons unless the drain outlet size is larger than 3/4. The most recent code is the International Mechanical Code (IMC). Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. Your HVAC or AC unit condensate should be trapped close to the unit Is this an acceptable form of condensate drainage? Prevent materials from entering and clogging roof drains and conductors and from spilling or migrating onto surfaces of other construction. I inspected a home earlier today and they had the AC condensate drainage into the (previous) laundry drainage. Condensate piping shall be sized in accordance with CMC Table 312.3. The AC/Heat works fine. Chapter 307.2.2 Drain pipe materials and sizes ( 2012 Mechanical Code) states: Where the drain pipes from more than one unit are manifolded together for condensate drainage, the pipe or tubing shall be sized in accordance with Table 307.2.2. Bob, continuingHere is Diversitech's 5/8" flexible AC condensate drain tubing - sold at Home Depot and at HVACR suppliers and plumbing suppliers, What type of piping or tubing is used for condensation drainage inside a wall on an inside unit of a split unit. An English company developed a toilet tank several years ago that uses both condensate and potable water for flushing. It says that it must be disposed of into an approved location and that it shouldn't be dumped on walkways, streets, or alleys as to cause a nuisance.. The IMC code doesn't directly state that the drain line must be insulated. Many will point to where the ICC energy efficiency code states: N1103.3 Mechanical system piping insulation. I have a question regarding the use of a Condensate Removal Pump for a hybrid water heater. As far as trap requirements, the IMC leaves them in the hands of the manufacturer. This way my line set can be routed hidden up into the attic above and run to an adjacent wall which is exterior and pass through to the outside. You will not receive a notification when a response to your question has been posted. . Excerpt: The condensate drain does not require a trap. Kelli I need to understand more details of the situation - but in general the answer is sure - properly-connected. Thank you. UV resistant wrap for linesets 4. . Theres one final little touch Id like to pass on to you. This is in a ground level garage. Does this sound right? Really? Meanwhile COMPARE these example instructions that discuss proper condensate drainage for a condensing tankless water heater: Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. @Sean Marlow, Multiple pipes in a manifold configuration shall be sized in accordance with an approved method. Loose earth free from rocks, broken concrete and frozen chunks shall be placed in the trench in 6-inch (152 mm) layers and tamped in place until the crown of the pipe is covered by 12 inches (305 mm) of tamped earth. My a/c in my apartment was under performing , so I took a look at the F.A.U. Lets take a look at what the codes say about condensate control and adherence to the code when doing an HVAC change-out. . The following are significant changes to the IMC and its proposed amendments. On 2020-01-16 by (mod) - placing an air handler on top of mason bricks sitting inside the drip tray proper installation procedure? Only one image can be added per comment but you can post as many comments, and therefore images, as you like. As far as sizing goes, we use 3/4 inch Schedule 40 PVC drains for all residential HVAC. A condensing gas-fueled tankless water heater would be expected to operate at a greater overall fuel efficiency than a comparable non-condensing unit. You wont be able to say, well, I just joined into it right there and thought the rest would be okay!. (IRC), International Building Code (IBC), International Plumbing do not discharge HVACR condensate over a sidewalk. You can find the first article here HERE if you missed it. The secondary drain had a wet switch installed in the outlet port. It's this an acceptable install? And that piping needs to have a certain slope to it. Terminology Usage in the Code of Practice . Sir my one question is it me handel 90 tr dx centerl plant and screw compressor but customer requirements is no air re sarulation .because of progress site toxic type smell his requirements is a 100/.present fresh air in throw cooling coil and in the process site also exuast air out.so Plz give me best system design. -- [Thanks to Al Carson, Carson Dunlop Associates, Toronto], Note: new in 2015 is the ICC IMC 307.2.5 & IRC M1411.3.3 Drain Line Maintenance code for 2015, The ICC, under "Drain Line Maintenance" requires that, Condensate drains shall be configured to permit the clearing of blockages and performance of maintenance without having to cut the line. vibration combined with condensation (and perhaps actual condensate) between the brick surface and the metal housing of the air handler invites corrosion and over a longer term, damage to the unitA vibration isolating pad such as the Wagner MP-6E EVA Anti-Vibration Pad 6x6 Inch Square by 7/8 Inch Thick pad shown below is a better practice. If you have an iPhone, subscribe to the podcastHERE, and if you have an Android phone, subscribeHERE. If you are making use of a water heater - to produce domestic hot water used for washing and bathing - water flowing through the heater is pushed by building water pressure, from a municipal supply or from a well water pump or a pressure booster pump. 2. It appears that this condensate drain only drops into that vertical standpipe an inch or two and if there is still a decent opening around it to let air into the standing drain line then you got an air gap between the end of the condensate drain and the P-trap below so it should be okay. 9.1.10 Air Conditioning Equipment. On 2020-05-14 by (mod) - warranty company will not cover modification to my condensate drain line. Table 307.2.2 states: "3/4 up to 20 tons" Is this the same code you are referencing? General 9. Using California's Title 24 as a good example, see the table below. Infiltration Skeletons Behind Closed Doors w/ Genry, All fuel-burning appliances require oxygen to burn. The flood-level rim of the receptor shall be not less than 6 inches (152 mm) lower than the lowest Mechanical system piping capable of carrying fluids above 105F (40C), or below 55F (13C) shall be insulated to a minimum of R-2. For the secondary drain system he installed a wet switch within the pan below the unit which will turn the unit off upon water detection. Don't dump condensate around foundations, basements, or other areas that could cause ponding, erosion, or leakage. P.S. The complex is now owned by a new owner and he has contacted us about why we didn't insulate the condensate drain lines that are inside the return air in an air conditioned space. health and safety concerns are reviewed. 5.2A Roof Drainage Terminology as used in the COP. [6] Simpson Strong-Tie, "Code Compliant Repair and Protection Guide for the Installation of Utilities in Wood Frame Construction", web search 5/21/12, original source strongtie.com/ftp/fliers/F-REPRPROTECT09.pdf, [copy on file as /Structures/Framing/Simpson_Framing_Protectors.pdf ]. If the drain line includes waste from a condensing furnace, it will create a more acidic waste type that needs to make it to the ground. Viper Condensate Pan and Drain Treatment Viper Condensate Pan and Drain Treatment is a sprayable gel. Many will point to where the ICC energy efficiency code states: N1103.3 Mechanical system piping insulation. @John W., This lightweight tool significantly reduces prep time by quickly and consistently beveling when doing multiple cuts. But you still need to confirm to yourself that the ENTIRE drain line has at least, an eighth-inch slope to it. AMERICAN COMMERCIAL CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL [PDF] This gives your drain pipe a uniform look and makes it easy for the inspector to pass your job. Because typically the installation instructions for a condensing tankless water heater include this statement: A transitioning civil engineer and quality inspector with oil and gas, civil construction experience, capable of working independently with minimum supervision, and committed to providing high quality service to every project, with focus on health, safety and environmental issues. . Here is an excerpt from the Uniform Mechanical Code pertaining to the disposal of air conditioning condensate: Condensate from air washers, air cooling coils, fuel-burning condensing appliances, the overflow from evaporative coolers and similar water supplied equipment or similar air conditioning equipment shall be collected and discharged to an approved plumbing fixture or disposal area. Apologies for the delay. An old foreman of mine always liked to glue in his PVC with the lettering facing away from the perspective of the person sitting on the platform. Im not sure if this is relevant to the answer, but the water heater has a neutralizer built in so that shouldnt be an issue either way. I would think you need to look at the bigger picture as to where the condensate drain is connected. Certainly there is no conceptual constraint on where a condensate drain can be located, but it has to be in a location that works either by gravity or by a condensate drain pump. eCodes@iccsafe.org. These. Youve installed the new system and now that youve adapted into the existing drain line, you own the whole drain line. Think of it as similar to a dishwasher installation. If youre planning to tie two evaporator drains into one single drain line, they may want you to increase the size of the final pipe going to the outside. Experienced in data aggregation, data<br>cleaning, data analytics, data visualisation, data calculation, problem . The Sabik 500 has been designed to provide balanced and sustainable ventilation whilst incorporating modular features and user friendly controllability resulting in a high efficiency, market leading ventilation system. AND DRAIN TRAP INSTRUCTIONS, Intertek CVC96 7 MVC96 TWO STAGE GAS FURNACE INSTALLATION INSTRUCTIONS, RECTORSEAL EZ TRAP CONDENSATE DRAIN LINE INSTRUCTIONS, RHEEM NON-CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL, AMERICAN COMMERCIAL CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL, ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, 307.2: " Condensate shall not Bottom line: The model building codes require a P-Trap on all plumbing waste lines that is connected to a sewer. When the AC condensate drain entry point is higher than the condensate drip pan outlet you have to either use a condensate pump - which is what I'd do - or disassemble and re-install the whole AC/Heat system to raise it so that it can drain by gravity. Provided an air vent and drain plug in the coil. An effective communicator with excellent relationship building & interpersonal skills. The full text of the code is available through ICC, and the proposed amendments are available through the North Central Texas Council of Governments (NCTCOG). Just curious. I'm preparing to install a DIY mini split on the back wall of my garage which is an interior wall. DavidThe overflow drip pan can be capped off provided that there is a water sensor switch installed that will shut down the AC system if the pan receives condensate water. 2019 CALIFORNIA MECHANICAL CODE RESIDENTIAL CONDENSATE DISPOSAL REQUIREMENTS . As far as I know, the EZTrap does not have a vent. We cannot have condensate runoff drain to public walkways and driveways. Were required to get a strap on it every four feet. Uniform Mechanical Code. Both require an air gap - which you have, and neither should be overwhelming a properly-sized, un-blocked drain. Hey, so we recently brought a house in MA and have come across this: the HVAC is connected to a standpipe for a washer via a tube. Does anyone have any information about this topic? On 2021-06-03 Bob,In new HVAC condensate drain installation when the drain is run through framed walls, use of a flexible plastic drain line is common - as shown in the photo I'll attach below and as is described further at inspectapedia.com/aircond/Condensate_Drain_Problems.phpHowever in my OPINION a better installation uses rigid PVC pipe, properly sloped 1/8" to 1/4" per foot. Wow, this blog got a little long! A neutralizer is easy to make with a length of 1 1/4 pvc pipe and some marble or lime chips. Opening/closing doors and windows can also worsen the issues that stem from infiltration due to upsetting the balance of pressures in the home. Obviously, I need to ask the builder why he didnt use the sink in the laundry room. Anything over 20 tons uses larger diameter piping. Also, about that shared drain idea, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. The closest to building code specifications that you will get for the question you post is the general requirement to install materials following the manufacturer's instructions. . The tables of pipe insulation shown here are interesting in that each gives insulation thickness required in inches without specifying the insulation material though Table 503.2.8 does give an assumed R-value per inch of insulation. This is part two in a series on a deeper look into the sensible heat rate equations. @Hy, The return air flowing through return ducts into an A/C air handler may be high in moisture. Since there is a lot of room for inaccuracy in extreme climates (especially those with high latent loads), many HVAC systems are oversized and underperform. 310.3.1 basically says its not reasonable to ask a future technician who has to come out to clear a blockage, to cut the PVC lines in order to do so. To know what this code is about, you can read it in the article below. The problem is the water from condensation has been leaking from the drip pan. @jacinto raquel, In practice, it is safer to use 1/4 of fall per foot to ensure proper drainage and provide some wiggle room for error. Condensate from air cooling coils and the overflow from evaporative coolers and similar water supplied equipment shall be collected and discharged to an approved plumbing fixture or approved disposal area. See also INSULATION R-VALUES & PROPERTIES. In SC, does the condensation line of an attic HVAC unit need to be insulated? When doing load calculations (Manual J), we need to know how much of the heat load, especially the latent heat load, comes from leakage in the building envelope and the ducts. Mechanical Specification Condensate Trap 2 Nikki Lane Natural Bridge Station, VA 24579 Phone: 540.228.1967 . Thats pretty much common sense, right? what is connection from the evaporator condensate pan to the pvc drain line and what is the material required? Need code reference. Alternatively, should this line have a vent just after it exits the water heater and possibly a small trap before it joins the main line out to keep insects out? The black tubing in the photo is actually foam insulated refrigerant piping. On 2021-10-01 by inspectapedia.com.moderator - how far away can I install condensate p-trap? The method of drainage shall comply with applicable Federal, State, and local laws and regulations relating to pollution control or the protection of the environment. Strong . Air Conditioner Condensate Drain Code The International Mechanical Code (IMC) provides specific rules and regulations on how to install, clean, maintain, and repair your HVAC condensate drain lines. Does Texas code require an attic AC drip pan to be be attached to a drain line or is it acceptable for the drain line to be capped off? An example is this VENT-EXHAUST EXTERNAL TRAP INSTRUCTIONS [PDF] posted by Questar Gas. To clarify, an indirect waste pipe is something that is upstream of a trap. When we are mounting to the deck, I use cut-off PVC piping to create stanchions, and reinforce the downward grade, off the service platform. The IMC (International Mechanical Code) is one of the most widely utilized and referenced. There was considerable discussion of the condensate disposal requirements. Plz share the about TFA system what is a actually suction pressure and how is it work, Treated Fresh Air Units (TFA) are also known as Fresh Air Handling Units (FAHU). [7] 2006 ICC Model Building Code Chapter 3, General Regulations, New Jersey Mechanical Code, web search 8/2/2012, original source: http://www2.iccsafe.org/states/newjersey/NJ_Mechanical/PDFs/2006_Chapter%203-General%20Regulations.pdf. Short answer: On 2020-05-18 by (mod) - overflow drip pan can be capped off provided that there is a water sensor switch. Enter the email address you signed up with and we'll email you a reset link. I'm still searching for a check valve that only allows the water to run down and put but stops potential gases from migrating up as a backup but so far no luck. We have to use an approved corrosion resistant pipe like Schedule 40 PVC. If the manufacturer requires a trap, then a trap is required. Bush down the ends, and you have a simple package. It's possible that the owner has got a report from an inspector who, under the aegis of being through, reported this condition as a concern or possible concern. An example that you will see in some installation instructions used for equipment that is draining through an appropriately sloped drain line with no trap whatsoever down into a condensate pump that in turn pumps condensate to the disposal point. Air Conditioning Condensate Handling defects lead to condensate spillage, leaks, mold. ABS materials will not put out toxic smoke. While venting is a common best practice, it isn't part of the IMC code. Another important topic is covered by the code books and installation manuals for the equipment being installed. The 2015 version of the IMC section 307 is what I will be referring to in this article. origin ZIP Code, destination ZIP Code and time of acceptance and will depend on shipping service selected and receipt of cleared payment. On 2022-06-21 1. We have all kinds of great videos about your homes hvac system. Some condensate products might be too hot for the piping used for an HVAC condensate drain - such as that thinwall flexible plastic tubing found at many installations, (condensate from a condensing tankless water heater is at about 38C or about 100F) but standard PVC pipe, if that's what was used for the drain, should be OK. Does anyone have any information about this topic? 9. Condensate waste and drain line size shall be not less than 3/4-inch (nominal) diameter from the drain pan connection to the place of condensate disposal. What to do When Your Heater Stops Working After a Storm, 14 HVAC Clichs to Avoid: Salespeople and Their Unoriginal Myths. My "guess" is that the reason those pumps are excluded is an effort to avoid leak and mold damage liability. Venting after the trap (like shown on the EZ Trap above) is an excellent idea in most applications because it helps prevent airlock that can occur due to double traps and shared drains. while submerged in water. The code as it relates to condensate disposal in the IMC is pretty vague. A point I want to make to installers: we can get caught up in this little 6 by 4 area were installing in and not be mindful of the complete drain line. @Amy, Plumbing Code (UPC) and the 2005 National Electrical Code." Mechanical Code (IMC) January 1, 2023. Remember that the enforcement of the various regulations of the code varies with jurisdictions. Im not here to pretend I know or could even interpret all the codes correctly. My warranty company will not cover modification to my condensate drain line because the "items not covered" in my contract list the condensate pump.". Shipping to 240+ countries worldwide. And this can be in a planted area that is large enough to accept the amount of drainage, and soak down into the earth.
Disadvantages Of Minimally Invasive Heart Surgery,
Chicagoland Speedway Redevelopment,
Prayer Points Against Untimely Death With Bible Verses,
Articles M