P.S. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. First, you need to set the time, which is good to know in case of a power outage, or daylight savings adjustments. Date Listed: 18/02/2023; . I visually checked the clock motor and it was good. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. {
Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. I have a 2 speed pump. "@type": "ImageObject",
Why do we stock so many pool parts? Wont work manually or by timer function. make sure it hasnt tripped and is switched on. There is a switch control panel and replaced the 20amps DP switch as well. That will do it. This page is fantastic!! In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Theres really only 3 causes as to why your pump wont turn on/off. Is there a control board, PCB in the panel that could have problems? If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. Faulty Pump or Wiring from the Timer to the Pump. I have to reset the time every day. I made sure the trippers were fully inserted and tight. Not sure if i need to check out the wiring, but it is a bit frustrating. I unscrewed the clip and put it back on and its still doing the same thing. When the trippers are done up, you shouldnt be able to move them with your hands. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). The mechanism for the off tripper doesn't work at all when manually depressed. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. "width": "611",
If not, the motor may be failing. We cover T101, T103 and T104 models of mechanical pool timers. "datePublished": "1/10/2020",
I guess if they look the same as before maybe the dial is warped? Im wanting to use T101 to wire my above ground pool pump. Tighten them with a wrench. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 These clocks determine when your pool pump turns on, and how long it runs. You can replace the entire mechanism or the gears. Assuming the wiring is all correct. "name": "In The Swim",
Ive seen it happen from lightning strikes, or insect infestation. Just replace it and hope for one that isnt defective. Copyright 2022 In The Swim. I hope this helps. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. As it get cooler you can cut it down to 5 or 6 hr a day .
4 Beds. You can replace it but its really just easier to replace the entire mechanism. Flip it from where it is now, to the opposite side. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Intermatic Pool Timer, tips & troubleshooting So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Only perform this step if you are qualified. Pull the timer out and turn it to the correct time. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. Move the start and stop pins to appropriate times for swimming pool filter operation. Jump to the troubleshooting steps below to fix the issue. It loses about 1.5 to 2 hours per day without any outages. 2. You need that 8 hr run in just the summer . Any guidance on how to fix this? Put a meter on the wires or trace them back to find out their voltage and source. DEWENWILS Outdoor Outlet Box. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. My Tork TU40 pool pump timer wont turn on the pump. The red - JustAnswer I have Model T40004RTe. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. At some time the timer was disconnected and the pump wired direct to the breakers. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Sometimes during power surges or lightning, these will be fused together and not come apart. Set the current time to the center time pointer, pointing downward at 6 oclock. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! please help me. I have the Intermatic T103 autotimer on my pool. The old "off" tripper was fractionally bent. That should quiet it down. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. "@type": "Organization",
Could also be grit or insects inside of the gears of the clock motor. Flip off the breaker. AJH Trade Group also participate in other affiliate programs. The timer quit after a nearby lightning strike. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Simply screw it back into place until its snug. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. The timer appears to be working fine (keeps time). do i need to do something different? The problem lies where the power dies, youve probably heard that before. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Thank you so much. How do you know if your pool timer is bad? March 16, 2022 by WildRiverCountry. Back when I was a young technician I was taught to always look for the easy things and use all my senses. Step 3 Was a good island when all the day trippers left Above you said to connect white to A. and Black to 1what do I do with red? The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. If I have to tell you which terminals to measure, you shouldnt be doing this! Any suggestions? If you loosen the hold down screw to much it could separate from the timer pin. "headline": "Intermatic Pool Timer Troubleshooting",
Phil. Timer not tripping pump on. Turn the metal bar until it contacts one of two plastic side tabs. A wire inside the motor may be touching another wire, or the metal sides of the motor. Reset the clock to the correct time. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. If you cant, is the manual switch stuck or jammed? I took the electrical box cover off and check the breaker connections. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. Hi Bob, you have two blacks and one neutral? It sounds like the Line and Load wires are reversed. }
. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. View community ranking In the Top 5% of largest communities on Reddit. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. I turned the breaker off and back on and still not working. I believe its the manual on/off switch that is the problem. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. This will disengage the dial and allow you to spin it in either direction. I not sure if this is the best timer to use. Is power reaching the time clock? Pool timer malfunction - DoItYourself.com Community Forums You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Should You Get a Pool Pump Timer? You off course will want to adjust one time pin at a time. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. "@type": "ImageObject",
"publisher": {
I looked through the visual motor check and the gear still moving fine. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Is there anything else I can do or do I need to get a new one? Terminals 2 and 4 are used for wires going to the load (pump). Should I go ahead and spray it anyway? Or be loose and not making good contact. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. What Causes Problems With Intermatic Timers? - Reference.com ), you should be able to discern if this is the problem, which could mean a new clock. Pool pump timers can last up to 20 years, depending on the model. The rest of your setup is probably fine. It should loosen up after a few goes when the grease and gunt dissolve. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. David, check the wiring, the power in and power out wires may be reversed. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. 120Volt Tork 1101 timers can be fixed with repair parts. And when switched on, power to the load terminals? I look through the window of the panel and see the gears running well. i would like to use a timer but am now afraid to try another. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. A power surge may have taken out the timer or the pump. Sometimes the trippers get loose or damaged. With the breakers turned off, remove the mechanism from the box. Garden Guides | How to Troubleshoot a Swimming Pool Timer If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Timer not tripping pump on. NEW CONSTRUCTION. be sure the pins are pushed onto the edge of the dial fully. If the pump doesnt come on, follow the steps below. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. It worked for a day but the day after it didnt work. Stupid third question, but does the ON tripper say ON? Replaced complete new timer assuming 5 years perfect service probably wore it out. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. Hi Rhomell, are you sure you got the correct trippers? Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? The circuit is protected by two ganged breakers. it could also be a failing breaker, but that would be a last resort. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. 2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts "@type": "Person",
Articles and resources for swimming pool owners and DIYers. There is a second switch between the breaker and the timer. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Thanks in advance! Does the tripper work on other areas of the clock, like near the off tripper? It just seems to have a weak start?? Are the trippers slid all the way onto the dial fully? To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Please let me know if you find the solution! Why is my water heater timer not working? - Quick-Advices The most common pool timer used for inground pool pumps is the Intermatic time clock. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. I would suggest calling Intermatic and suggesting that idea and a free replacement? Advice? Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. I flicked the switch between on and off and it will not shut off. Now remove the terminal cover on the timer. Other causes include rusted springs, insect infestation and loose timer dogs. Same way, WD-40 or any light lubricating oil. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Check that the breaker is firmly pushed onto the bar, and is not loose. If its not, then the timer will not turn on/off at the correct times. Is the timer repairable, or should I just install a new one? The tripper will not move. Everythings OK now, unit works just fine. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. Repeat the process for the "on" pin. There should be an off pin and an on pin. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. "author": {
Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. You dont have two OFF trippers, right? Now Im having to turn my pool pump on and off manually. How can I fix this? The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. We may earn a small commission. You will first want to look at the pool timer and see if you have two timer pins. Wont power on pump but can hear timer clicking away. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Align the bar with the current time and push it back into place. Hi Davy, The problem is the 'off' tripper. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. Pool co says T104 timer needs replacement and filter cartridge. Timer must be reset for current time after power outage. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Not sure if you still answer these but I have a weird one for you. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. I noticed that they had stopped. A recent power outage will cause the timer to stop working. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Is it keeping time normally? My pump has a plug. The timer not working is for the pump. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. Thanks for any help you can give. I think I have found it. It is still moving and it will trip off but not on. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Thanks. I manually turn it on timer is running, it will trip pump OFF. Can breaker be bad? Hi, hope you are doing well. It could also be loose wires, either on the time clock terminal board, or on the timer motor. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. Your email address will not be published. Or may be bent and not come together. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Gently tighten the screws to securely hold the dogs in place. I am using the breaker to turn on and off the pool pump. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. Is the ON tripper all the way pushed onto the dial? I called Intermatic and there is nothing you can do except check it every time you have a power loss. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. sometimes Im forgetful lol what are your thoughts? If I manually push the lever, it moves without much pressure. The 12 Best Pool Timers of 2022 - WildRiver Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. Dont know what the issue is. The position of the metal bar forces the gear next to it to turn one way or another. I tried to change the on tripper due to Daylight savings time & dropped the screw. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. How Do You Set A Pool Pump Timer? - Pool Pro Answers After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Jul 20, 2021. Line is incoming, Load goes to the pump. Reasons Why Pool Timers Stop Working 1. Hi there, 'Why not Toowoomba?': Tourism body says water park a missed opportunity The pump worked perfectly before I unscrewed it. My intermatic pool timer will not automatically turn on. I - JustAnswer How to Install the Trippers on Intermatic Timers | eHow Terminal A (farthest to the left side) is not connected to anything. You will want to make sure the manual switch under the timer wheel is pushed to the on position. Almost like it doesnt have the strength to click the timer on or off. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. Is it Necessary? http://waterheatertimer.org/Tork-timers-and-manuals.html But my new timer will not work either. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse.